Battery Runtime Calculator

Battery runtime is usable battery energy divided by the actual load, adjusted for depth of discharge, efficiency and a planning reserve.

A 12.8V 100Ah battery running a 100W load can provide approximately 9 hr 32 min under these assumptions.

Enter your battery and load

Use the units printed on the battery or power station.
Use the rated nominal voltage, not the live meter voltage.
Average appliance draw, including any always-on accessories.
The share of rated capacity you plan to use.
Use 100% only when conversion losses are not material.
Energy intentionally left unused for uncertainty.
ESTIMATED PLANNING RUNTIME
9 hr 32 min

9.54 hours · 953.9Wh planned energy at the load

Calculated estimate, not a guarantee. Verify that the battery and inverter can supply the load.

Energy breakdown

Nominal battery energy1,280Wh
After depth of discharge1,152Wh
Conversion loss92.2Wh
After planning reserve953.9Wh
Battery-side draw108.7W
Decimal runtime9.54 hours

1,280Wh × 0.90 × 0.92 × 0.90 ÷ 100W = 9.54 hours

QUICK REFERENCE

Battery runtime by capacity and load

These are calculated planning estimates using 90% depth of discharge, 92% system efficiency and a 10% reserve—the same defaults as the calculator.

Estimated runtime at common battery sizes and continuous loads
Battery capacity 25W 50W 100W 250W 500W 1,000W*
256Wh7h 38m3h 49m1h 54m46m23m11m
512Wh15h 16m7h 38m3h 49m1h 32m46m23m
100Ah at 12.8V
1,280Wh
38h 9m19h 5m9h 32m3h 49m1h 54m57m
200Ah at 12.8V
2,560Wh
3d 4h 19m38h 9m19h 5m7h 38m3h 49m1h 54m

Calculated, not measured. Values assume a steady load. *A runtime figure does not mean the battery, BMS, inverter or power station can safely supply 1,000W; verify continuous and surge ratings.

REAL-WORLD PATHWAYS

Start with the use case that matches yours

Trolling motor

Estimate from motor current and battery amp-hours, where speed and water conditions matter.

12V battery systems

Use the dedicated 12V tool for watts or amps and system-specific guidance.

100Ah LiFePO4

See focused 100Ah examples without turning this broad calculator into a duplicate guide.

Other common setups: For laptops, workstations, routers and Wi-Fi, enter measured average watts when possible. For a cycling 12V fridge, use average power over a representative period. For a portable power station, select rated watt-hours and match efficiency to its AC or DC output.

TRANSPARENT METHOD

Battery runtime formula

Watt-hours (Wh) measure stored energy. When a battery is rated in amp-hours, nominal energy is Wh = V × Ah.

Runtime (hours) = nominal Wh × depth-of-discharge fraction × efficiency fraction × (1 − reserve fraction) ÷ load W

Depth of discharge limits how much nominal energy is used. Efficiency accounts for conversion losses; for an AC appliance this normally includes the inverter. The reserve then leaves a planning margin. An equivalent load-side view is to divide usable battery energy by battery-side draw, where battery-side W = appliance W ÷ efficiency.

See the full PowerUseLab methodology for the broader calculation policy and limitations.

Assumptions and limitations

  • Use average load. Startup surges, cycling appliances and inverter idle draw can make a nameplate watt figure misleading.
  • Use manufacturer limits. Battery-management cutoffs, allowed depth of discharge and continuous output ratings take priority over a calculated estimate.
  • Allow for conditions. Temperature, battery age, wiring loss and discharge rate can change available energy. Lead-acid capacity is especially sensitive to high discharge rates.
  • Match the power path. AC inverter losses and direct-DC conversion losses differ; enter an efficiency appropriate to the actual setup.
COMMON QUESTIONS

Battery runtime FAQ

How do I calculate how long a battery will last?

Convert the battery to watt-hours, apply usable depth of discharge, efficiency and reserve, then divide by the average load in watts. The calculator performs each step above.

How long will a 100Ah battery last?

It depends on voltage, load and usable capacity. Under this page’s defaults, a 12.8V 100Ah battery running a steady 100W load is estimated at 9 hr 32 min. Use the 100Ah LiFePO4 runtime page for focused examples.

Why is real-world runtime lower than Wh ÷ watts?

Rated Wh is nominal energy. Depth-of-discharge limits, conversion loss, standby draw, temperature, battery age and a variable load can all reduce actual runtime.

Does LiFePO4 last longer than lead-acid?

Not automatically for the same usable watt-hours and load. In practice, manufacturer-approved depth of discharge and discharge-rate behavior can make the usable share different. Compare using each battery’s specifications.

How does inverter efficiency affect runtime?

An inverter draws more power from the battery than the AC appliance receives. At 92% efficiency, a 100W appliance represents about 108.7W of battery-side draw before other unmodeled losses.

Can I calculate power-station runtime from Wh?

Yes. Select “Rated watt-hours (Wh),” enter the power station’s rated energy and use an efficiency appropriate to its AC or DC output. Also verify that its output rating supports the load.

RELATED CALCULATORS